Home | HVAC Products | Tankless | Fireplaces | Gas Boilers | Services | Contact Us | Specials | Showrooms | Service Request | Get a Quote
Trinity Ti

Home : Gas Boilers : Trinity Ti
Trinity Ti

Gas Boilers - Trinity Ti
GENERAL TRINITY DOWNLOADS
Trinity Ti Installation Manual - Revised July 2010
Instructions d'installation et d'entretien
***TS-80 INSTALLATION MANUAL (NEW)
TRINITY TECHNICAL AND SERVICE DOWNLOADS
Trinity Ti T2.0 Trouble Shooting Flow Chart
Trinity T T1.0 to T2.0 Trouble Shooting Flow Chart
Cleaning and Service Procedure
Brazed Plate Hx Head Loss Curves
TOP TEN ADVANTAGES OF THE TRINITY
. Available in both Natural Gas and Propane versions with a modulation system that eliminates additional models
. State-of-the-art sealed modulation combustion system with hot
. surface ignition
. Patented 316L stainless condensing heat exchanger provides ultimate efficiencies
. All connections are conveniently located for ease of installation.
. Wall mount configuration saves valuable floor space
. Vents easily with conventional ABS, PVC or CPVC plastic piping
. The TRINITY has industry-leading modulation rates, which significantly increases comfort while reducing cycling and fuel consumption
. The distinctive casing design reduces costly standby losses, while virtually eliminating combustion noises
. High-capacity plate heat exchanger on combination models provides ample domestic hot water
. The TRINITY is certified, designed and rated to strict CSA, AGA, ASME and CSAus codes
GENERAL SPECIFICATIONS:
Ti100 |
Ti150 |
Ti200 |
Ti400 |
|
Size (D x W x L) |
14" x 15.5" x 22" |
14" x 15.5" x 22" |
17" x 15.5" x 22" |
23.5" x 21" x 36" |
Weight |
80 lbs. |
80 lbs. |
110 lbs. |
205 lbs. |
Max. Pressure |
30 PSI |
30 PSI |
30 PSI |
145 PSI |
Gas Type |
Natural, Propane |
Natural, Propane |
Natural, Propane |
Natural, Propane |
Max. Vent |
105' equivalen |
105' equivalent |
105' equivalent |
4"-30, 6"-65 eqv. |
Gas Connection Size |
1/2" NPT |
1/2" NPT |
1/2" NPT |
1/2" NPT |
Max. Supply Water |
200°F |
200°F |
200°F |
200°F |
Min. Return Water |
40°F |
40°F |
40°F |
40°F |
Oxygen Tube Barrier |
Required |
Required |
Required |
Required |
Certification |
CSA, AGA, CSAus, *ASME |
CSA, AGA, CSAus, *ASME |
CSA, AGA, CSAus, *ASME |
CSA, AGA, CSAus, *ASME |
HEATING SPECIFICATIONS:
Ti100 |
Ti150 |
Ti200 |
Ti400 |
|
BTU Input x 1000 |
15-100 |
25-150 |
25-200 |
75-399 |
BTU Output x 1000 |
14-95 |
23-142 |
23-190 |
71-379 |
S.S Efficiency |
98% |
98% |
97% |
96% |
AFUE |
95.1% |
95.1% |
95.1% |
95.1% |
Head Loss @ GPM |
12' @ 8 |
12' @ 8 |
13' @ 10 |
9' @ 20 |
Supply-Return |
3/4" NPT |
3/4" NPT |
1" on H, 3/4" on C Models |
1 1/4" NPT |
Boiler Modulation Ratio |
6.6:1 |
6:1 |
8:1 |
5.3:1 |
Flow Switch |
Optional |
Optional |
Optional |
Installed |
DOMESTIC HOT WATER:
(Combi version)
Ti150 |
Ti200 |
|
Supply-Return |
3/4" NPT Outlet 1/2" Inlet |
|
DHW Pressure Drop |
1 PSI |
|
Head Loss @ GPM |
15' @ 8 |
18" @ 10 |
Temperature Regulation |
Electronic Modulation |
|
D.H.W. Outputs at |
4.0 @ 110°F |
5.5 @ 110°F |
45° Inlet Water |
3.5 @ 120°F |
4.8 @ 120°F |
(GPM @ Water °F) |
3.1 @ 130°F |
4.5 @ 130°F |